About CompanyTechnologyProductR&DConsultationCustomer
Product
Controllers and Resistors
Controllers and Resistors
Total Article 8.  Total Page 1 / 1
Auxiliary Relay: WRAX-L440, DC 24, 33.5, 5... 
* Overview and Features
- Plug-in type, uses back and front-type sockets.
- Easy cabling and replacement .
- Long operation and fixed contact bars and two contact points per contact bar achieved reliable contact against vibration of the train.
- The arc chute made of alnico magnet blocks small and medium current.
- The contact is made of arc-resistant and abrasion-resistant AgCdo and coated with gold (Au). Can be used for controller small current.
* Uses: Composition of the control circuit of the electric train
Protective Relay 
* Structure and Operation
- The protective relay consists of the frame made of phenolic resins and the transparent plastic cover preventing alien substances from entering into the contact point and the machine.
- The protective relay has latchet-type structure. When contact point "b" is closed as the reset coil is excited, contact point "a" is closed by the latchet. At the same time, the armature of the reset coil leaves and contact point "b" is opened.
Item Description
Use Applied to the latchet relay for train vehicles
Rated Voltage DC 100V
Voltage Range DC 70~ 110V
Withstanding Voltage AC 1200V 1 Minute
Insulation Resistance 1000V MEGGER 100㏁ or higher
DC Voltage Relay: DC 1500V 
* Overview and Features
- Receives DC 1500V voltage in the DC part with the pantograph rise.
- Prevents Main Circuit Breaker (MCB) tripping by panto. that is running into wrong path due to no voltage when passing DC-DC section in the DC area.
- Operates the DC Voltage Relay Time Relay (DCVRTR) to prevent malfunctioning of the successive circuit due to PT inrush current when inrushing AC section.
- Prevents accidents due to direct grounding between panto. and EGS during operation.
General Distribution Panel 
* Overview The general distribution panel is used in the electric train, and connects contactors, relays, distribution breakers, and switches on the steel panel. On top and on bottom of the general distribution panel, there are port panels installed for convenient internal/external cabling. * Composition The distribution panel is installed at the back of the driving room in the TC car for other controlling purposes than cooling and heating. In M, T1, and T2, the distribution panel is connected at the end of the vehicle.
CM Starting BOX 
The CM starting box is for the Compressor Motor (CM) and supplies air pressure for braking the electric train and opening/closing the door.
Item Description
Circuit Type
Controlling Type
Cooling Method
Capacity
Bypass Operation Type
Operation Temperature
Operation Temperature
   Voltage-type Inverter
   PWM control
   Natural cooling
   27[KVA]
   Reactor operation type (65%)
   -25℃ ~ 40℃
   30% ~ 90% (Without dew condensation)
Input    Rated Control Power
   (Tolerance Range)
   Efficiency
  Rated Voltage
   Voltage Range
   Rated Frequency
   DC 100 [V]
   DC 70 [V] ~ 110 [V]
   90%
  Three-phased 380 [VAC]
   342[VAC]~ 428[VAC]
   [60 [Hz]
Output    Rated Output
   Rated Output Voltage
   Rated Output Current
   Rated Output Frequency
   Operation Frequency
   V/F Feature
   Overload Capacity
   Load Power Factor
   Operation Method
   Stop Method
   16[KW]
  Three-phased 380[VAC]
   32.4[A]
   60[Hz]
   0~10[Hz] adjustable
   Static torque
   150% of rated current, 1 minute
   82%
  Soft frequency operation
   Free stop
High-pressure Air Compressor Motor (CMDE) 
Overview
The CDME is for the Compressor Motor (CM) and supplies air pressure for braking the electric train and opening/closing the automatic door.
Item Description
C
M
D
E
 Circuit Type식 2-phased forced chopper + voltage-type inverter
nbsp;Controlling Type PWM CONTROL
Cooling Method Natural cooling
Input Capacity 27 KVA
Operating Temperature -25℃~40℃
Relative Humidity 30%~90% (Without dew condensation)
 Rated Control Power DC 100V
(Tolerance Range) DC 70V~110V
 Efficiency 90%
Rated Voltage DC 1500V
Voltage Range DC 900~1800V
L
O
A
D
 Capacity 15 KW
Output Voltage Three-phased 440V AC
Output Current 26A
Frequency 60Hz
Operation Frequency 0~10Hz adjustable Static torque
V/F Feature Static torque
Overload Capacity 150% of rated current, 1 minute
Load Power Factor 82%
Wire Wound Resistor: KS Product 
* Feature
- The wire wound resistor is the sand bushing coiled by the resistor wire and coated with insulation paint. It is easy to connect the wire wound resistor that is free from the secondary accident when the resistor line is cut.
- Non-inductive wire wound resistor is also available. Suitable for high resistance and small current.
* Basic Specifications
- Resistance Error: ±2%, ±5%, ±10%, ±20%
- Withstanding Voltage: AC1,000V for 1 minute
- Insulation Resistance: 20㏁
Main Resistor 
* Overview
The main resistor is installed in the DC resistor controlling type electric train and applied for braking.
* Functions
- The main resistor is connected to 4 pulling electric motor in serial or parallel and controls the speed of the electric train
- The main resistor consumes braking current through resistance during braking. (Installed in the lower part of the electric train and cooled by natural cooling method>
* Features
- Excellent corrosion resistance
- Uses STS304 with no lifetime changes in resistance to be strong against shock and vibration.
- Cut-free
- The resistant part is molded into the strip shape and fixed between special insulator s for excellent cooling effect and simple structure.